Thermal Oil Properties

Interpolate density, specific heat, thermal conductivity and kinematic viscosity at the required oil temperature.

Operating conditions

Choose the heat-transfer oil and enter a temperature within its tabulated range.

Valid calculation range: 0–320°C

Interpolated properties

Total Seriola K3120 at 200°C

Density760.0 kg/m³
Specific heat2.531 kJ/(kg·K)
Kinematic viscosity1.010 cSt
Thermal conductivity0.1200 W/(m·K)
Density0.7600 g/cm³
Convert pressure ↔ metres of this oil →

Interpolation method and units

Each property is calculated independently by linear interpolation between the two nearest temperatures in the supplied table. For Total Seriola K3120 above 300°C, values up to 320°C are linearly extrapolated from the 280°C and 300°C data points.

y(T) = y₁ + (T − T₁) × (y₂ − y₁) / (T₂ − T₁)

Engineering note: Results are based on the supplied reference table and are intended for engineering estimates. Values for Total Seriola K3120 above 300°C are extrapolated, not manufacturer-tabulated data. Confirm critical designs against the latest manufacturer data sheet and the condition of the oil in service.